va-Q-vip B

Details

va-Q-vip B is a vacuum insulation panel for construction applications.

va-Q-vip B is covered with a high barrier film and an additional black glass fibre textile for mechanical shock protection. The core itself is non-combustible (Fire class A1 in Europe). The va-Q-vip B with black glass fabric is inflammable (Construction materials class DIN 4102-B2). 

va-Q-vip B is approved for general construction purposes in accordance with the approval number Z-23.11-1658, of the “Deutsches Institut für Bautechnik (DIBT)”. 

va-Q-vip B panels have smooth edges and sharp corners due to special "edge fold technique va-Q-seam" so individual panels can therefore be joined almost seamlessly.

Applications

  • va-Q-vip B can be used in building applications for ceilings, walls, floors, flat roofs, top floor ceilings, exterior insulation behind panelling and insulation in wood frame construction.
  • Planners, installation partners or architects are responsible for the relevant specific insulation system. Application systems for buildings can also be discussed directly with Proctor Group Australia.

 Features

  • Official approval for building material with assigned thermal conductivity 0.007 W/mK
  • Significantly reduced heat flows from minimal thickness
  • Saves space thus providing a much larger usable floor areas or ceiling heights
  • Extra protective layer for reliable installation
 

va-Q-vip B

va-Q-vip B vacuum insulation panel



 

 Technical data 

Product Name va-Q-vip-B
Vacuum insulation panel covered with a high barrier film plus a black glass fibre textile for mechanical shock protection.
Surface Colour Black
Geometry Rectangular shape with flanges
Density (bulk, DIN EN 1602) 180-210 kg/m³
Thermal conductivity  
Initial value <0.0043 W/(mK) @ 20mm thickness (measured value)
Rated value including aging and edge losses 0.0070 W/(mK) for 20mm and greater thickness 
0.0080 W/(mK) at 10-15mm thickness
If aerated 0.020 W/(mK)
Temperature stability -70°C to +70°C
Thermal shock resistance Insensitive to heat and cold shock in the given temperature range
Humidity stability 0% to 60%
Internal gas pressure <5 mbar (at delivery)
Increase of gas pressure Approximately 1mbar/year (measure, 20mm thickness)
Standard dimension (LxW) 
I & II
I: 1000mm x 600mm 
II: 500mm x 600mm
Nonstandard dimension 
III & IV
III: Area > 0,10m² and <0,60m²
IV: Area <0,10m²
Special design Triangle, trapezium, corner cut, recessed surface and panel with hole, flanges folding by 10mm/15mm thickness
Nominal Thickness 10mm to 50mm

Size tolerance

0 to 500mm
501 to 1000mm

 

+2 / -4mm
+2 / -5mm

Thickness tolerance

 ±1mm

Specific heat

 0.8 kJ (kg K) (at room temperature)

Mass per area

 4 kg/m² (at 20mm thickness)

Compressive strength

 Approximately 150kPa (at 10% compression)

Flammability 

 DIN 4102 - B2

Service Life

 Extrapolated, depending on application up to 60 years.

 * For 10mm and 15mm thicknesses, if a flat edge is required, the flanges are refolded onto the main surface of panel.

All figures are intended as a guide. Please discuss with Proctor Group Australia when preparing specifications. 

 

Nominal Thickness to R-Value
 @ 10°C (Assigned by Deutsches Institut fur Bautechnil DBIt)
Nominal Thickness 
mm
Lambda/K Value/Thermal
Conductivity
R Value
10 0.008 1.3
15 0.008 1.9
20 0.007 2.9
25 0.007 3.6
30 0.007 4.3
40 0.007 5.7
 
 
CPD

   