Profloor Levelling System

Details

The Profloor Levelling System was developed in order that a level finished floor could be laid on a cambered, stepped or uneven
subfloor. The system will contribute towards meeting the statutory
impact and airborne requirements of the Building Regulations
depending on the subfloor construction.

The Profloor Levelling System complements the Profloor Dynamic
Batten System which is used on broadly flat and level subfloors to
provide impact sound insulation for party floors between flats and apartments. Profloor Levelling bases are also used for any building which requires a level finished floor to be laid on an uneven subfloor.

Types of Base

 

Levelling bases are manufactured from injection moulded High
Grade Polymer, size 70 x 100mm in three types: L, M type with 10mm (uncompressed) foam bonded to the base. Type H is for deeper floors with the foam bonded to softwood inserts of different thickness, which
fit under the levelling base.

Type L

  • Requires 21mm thickness battens
  • Floor depth minimum 51mm up to 67mm

Type M

  • Requires 33mm or 45mm thickness battens with packing 
  • Floor depth minimum 63mm up to 91mm with 33mm battens with packing
  • Floor depth minimum 75mm up to 103mm with 45mm battens with packing

Type H

  • Requires 45 mm thickness battens 
  • Floor depth minimum 93mm up to 203mm with packing.
    (All floor depths include 18mm boarding supplied by others)

Battens

Softwood, straight grained, 21, 33 or 45mm finished thickness x 45mm width, preferably length 1800 mm. Moisture content should not exceed 14%. Preservative treatment can be specified but is not usually considered necessary.

Board Flooring

For domestic use, 18mm C4 T&G chipboard with batten spacing of 450mm is adequate. Boarding such as 22mm chipboard, plywood or hardwood strip can also be used with appropriate batten centres recommended by the manufacturers. Closer batten spacing may be necessary for areas with higher loading ie. communal spaces.

For Non Residential Use

Please contact the Tecline with details of intended use, loading requirements and type of boarding to be used.

Key Features

  • Can provide impact and airborne sound insulation only on concrete floors with a mass greater than 300 kg/m²
  • Provides a level finished floor on uneven sub-floor, eliminating costly remedial work
  • Services can be placed incavity created
  • Quick to install
  • No need to glue to packing pieces
  • Total floor depth of system included an 18mm board finish that can be as low as 48mm and as high as 200mm
  • Allows for application of a variety of floor surfaces ie., chipboard, plywood or hardwood
  • Dry construction means no drying out delays

 

 
 